Roof in Ireland
to enlarge click here Findings: Severe swelling and waves, due to incompatibility between membrane and ventilation fan exhaust
Solution: Existing membrane replaced by a compatible one
Roof in Holland
to enlarge click here Findings: Protruding screws detached from sheet steel due to incorrect wind-load calculation
Solution: Membrane reattached and re-sealed with sheet strips

Drinking water reservoir in Australia
to enlarge click here Findings: Membrane disintegrated by intensive solar radiation and high temperature
Solution: Existing membrane replaced by an appropriate one
Roof in France
to enlarge click here Findings: Roof leakage, open seams due to a poorly welded membrane
Solution: Open seams re-welded and re-sealed with sheet strips

Roof in Belgium
to enlarge click here Findings: Total fire damage caused by rapid spreading of a fire due to high fire load content
Solution: Replacement building erected with considerably lower fire load in its roof structure
Roof in englishy
to enlarge click here Findings: Cavity formation in the vertical parapet connection of the membrane due to material shrinkage
Solution: Existing membrane replaced by dimensionally stable, application-related membrane